General Information
    • ISSN: 2010-0221 (Print)
    • Abbreviated Title: Int. J. Chem. Eng. Appl.
    • Frequency: Half-yearly
    • DOI: 10.18178/IJCEA
    • Editor-in-Chief: Prof. Dr. Shen-Ming Chen
    • Executive Editor: Alice Loh
    • Abstracting/ Indexing:  CNKI, Google Scholar, EBSCO, ProQuest,  Crossref, etc.
    • Email: editor@ijcea.org
  • Jul 14, 2026 News! Vol.17, No.1 has been published with online version   [Click]
  • Dec 31, 2025 News! Vol.16, No.2 has been published with online version   [Click]
Editor-in-chief
Prof. Dr. Shen-Ming Chen
National Taipei University of Technology, Taiwan
 

IJCEA 2025 Vol.16(1): 58-62
doi: 10.18178/ijcea.2025.16.1.840

Design of Cyclodextrin/Aptamer-Based Dual Recognition Fluorescent Sensor for Sensitive Detection of Galectin-3

Phoomintara Longsompurana , Nongluk Plongthongkum , Tassaneewan Laksanasopin , Rungtiva P. Poo-arporn*

  • Biological Engineering Program, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Thailand

* Corresponding author

  • Manuscript receivedNovember 20, 2024
  • acceptedFebruary 14, 2025
  • publishedJune 13, 2025

Abstract

Early detection of Heart Failure (HF) is crucial for enhancing patient outcomes, and recent developments in non-invasive biomarker sensors have enabled monitoring at the early stages to achieve this goal. In this study, we developed an HF detection platform targeting the biomarker Galectin-3 (Gal3), utilizing two specific binding sites: β hexakis-(6-mercapto-6-deoxy)-β-cyclodextrin (mCD) and an aptamer binding site. Computational methods, such as molecular docking, were employed to select and design an aptamer with enhanced binding affinity for Gal3. The engineered aptamer, Apt4_C15A, demonstrated strong binding affinity to Gal3, as confirmed through fluorescence assays, with a low equilibrium dissociation constant (<em>K<sub>D</sub></em>) of 3.20 ± 1.25 µM. The sensor was constructed as a sandwich platform, with mCD functionalized on silver-coated plates serving as the primary capture molecule and a 6-carboxyfluorescein amidite (FAM)-tagged aptamer serving as both the secondary capture molecule and fluorescent signal probe. The sensor exhibited high sensitivity, achieving a detection limit of 11.03 ng/mL within a linear range of 10–200 ng/mL, effectively covering clinically relevant Gal3 concentrations. This innovative mCD/aptamer-based fluorescent sensor demonstrated excellent detection performance, underscoring its potential as a reliable platform for early HF biomarker detection. Future improvements will focus on optimizing sensor fabrication conditions to minimize non-specific binding, further enhancing sensor accuracy and robustness.

Keywords

  • aptamer
  • cyclodextrin
  • fluorescent sensor
  • Galectin-3
  • heart failure
  • molecular docking
IJCEA-V16N1-840

How to Cite

Copied

Phoomintara Longsompurana, Nongluk Plongthongkum, Tassaneewan Laksanasopin, and Rungtiva P. Poo-arporn, "Design of Cyclodextrin/Aptamer-Based Dual Recognition Fluorescent Sensor for Sensitive Detection of Galectin-3," International Journal of Chemical Engineering and Applications, vol. 16, no. 1, pp. 58-62, 2025. https://doi.org/10.18178/ijcea.2025.16.1.840

Copyright & License

Copyright © 2025 by the authors. This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0).

Article Metrics in Dimensions

Copyright © 2010-2026. International Journal of Chemical Engineering and Applications. Unless otherwise stated

Published by